Fuel Pump Size Calculator

Every horsepower drinks at a rate the pump must guarantee.

hp
lb/(hp·h)

Formula

Flow (lb/hr) = HP × BSFC

Source / basis: Fuel-flow planning standard

Rated flow versus delivered flow

Pump datasheets quote free-flow at 13.5 V and low pressure. Real systems run 40–60+ psi of rail pressure, 12.5 V under starter load, hot fuel, clogged pre-filters and a pick-up that uncovers itself in corners. A pump that "supports 700 hp" on the box may deliver 500 hp of fuel in a stressed install. Buy flow margin — 20–30% over calculated — and verify with a fuel-pressure gauge under load.

Voltage is the silent killer: output drops nearly linearly with supply voltage. Alternator issues, long power runs and corroded grounds all shave pump speed and flow.

Pump flow needed (BSFC 0.5, gasoline)

HPlb/hrgal/hrL/hr
3001502594.63
50025041.67157.71
75037562.5236.56
1,00050083.33315.42

Worked Example

500 hp on gasoline.

  1. Mass flow = 500 × 0.5 = 250 lb/hr
  2. Volume = 250 ÷ 6.0 ≈ 42 gal/hr (≈ 158 L/hr)
  3. With 25% margin: spec ≈ 200 L/hr class pump at working pressure
Values here are for general reference. Exact conversions are unit arithmetic; estimated quantities carry the stated error margins. Verify critical decisions against manufacturer data.

Frequently Asked Questions

Why does E85 change everything?

E85 carries less energy per pound, so the engine burns ~35% more fuel mass per horsepower — and the fuel is "heavier" per gallon. Both effects compound into roughly 45% more volume flow for the same power.

Return or returnless?

Return systems keep cool fuel circulating and simplify multi-pump staging; returnless systems depend on precise regulator control. High-power builds usually end up return — heat management decides.